Atomistry » Magnesium » PDB 2bt6-2c3y » 2by0
Atomistry »
  Magnesium »
    PDB 2bt6-2c3y »
      2by0 »

Magnesium in PDB 2by0: Is Radiation Damage Dependent on the Dose-Rate Used During Macromolecular Crystallography Data Collection

Enzymatic activity of Is Radiation Damage Dependent on the Dose-Rate Used During Macromolecular Crystallography Data Collection

All present enzymatic activity of Is Radiation Damage Dependent on the Dose-Rate Used During Macromolecular Crystallography Data Collection:
3.2.1.1;

Protein crystallography data

The structure of Is Radiation Damage Dependent on the Dose-Rate Used During Macromolecular Crystallography Data Collection, PDB code: 2by0 was solved by H.-K.S.Leiros, J.Timmins, R.B.G.Ravelli, S.M.Mcsweeney, with X-Ray Crystallography technique. A brief refinement statistics is given in the table below:

Resolution Low / High (Å) 20.00 / 1.55
Space group P 21 21 21
Cell size a, b, c (Å), α, β, γ (°) 59.511, 66.646, 153.100, 90.00, 90.00, 90.00
R / Rfree (%) 14.6 / 17.5

Magnesium Binding Sites:

The binding sites of Magnesium atom in the Is Radiation Damage Dependent on the Dose-Rate Used During Macromolecular Crystallography Data Collection (pdb code 2by0). This binding sites where shown within 5.0 Angstroms radius around Magnesium atom.
In total only one binding site of Magnesium was determined in the Is Radiation Damage Dependent on the Dose-Rate Used During Macromolecular Crystallography Data Collection, PDB code: 2by0:

Magnesium binding site 1 out of 1 in 2by0

Go back to Magnesium Binding Sites List in 2by0
Magnesium binding site 1 out of 1 in the Is Radiation Damage Dependent on the Dose-Rate Used During Macromolecular Crystallography Data Collection


Mono view


Stereo pair view

A full contact list of Magnesium with other atoms in the Mg binding site number 1 of Is Radiation Damage Dependent on the Dose-Rate Used During Macromolecular Crystallography Data Collection within 5.0Å range:
probe atom residue distance (Å) B Occ
A:Mg1608

b:16.7
occ:0.85
O A:HOH2824 2.1 22.5 1.0
OD1 A:ASP540 2.2 14.5 1.0
CG A:ASP540 3.3 12.5 1.0
OD2 A:ASP540 3.6 13.8 1.0
NZ A:LYS572 4.1 23.3 0.5
O A:HOH2827 4.2 31.3 1.0
N A:GLY541 4.2 9.6 1.0
O A:HOH2829 4.3 15.0 1.0
O A:HOH2825 4.4 19.6 1.0
CE A:LYS572 4.4 21.5 0.5
C A:ASP540 4.4 8.4 1.0
CB A:ASP540 4.6 9.0 1.0
CD A:LYS572 4.6 19.5 0.5
CA A:GLY541 4.7 9.3 1.0
CA A:ASP540 4.7 9.0 1.0
O A:ASP540 4.9 9.1 1.0
O A:HOH2826 4.9 30.4 1.0

Reference:

H.-K.S.Leiros, J.Timmins, R.B.G.Ravelli, S.M.Mcsweeney. Is Radiation Damage Dependent on the Dose-Rate Used During Macromolecular Crystallography Data Collection? Acta Crystallogr.,Sect.D V. 62 125 2006.
ISSN: ISSN 0907-4449
PubMed: 16421442
DOI: 10.1107/S0907444905033627
Page generated: Tue Aug 13 22:06:33 2024

Last articles

Zn in 9JYW
Zn in 9IR4
Zn in 9IR3
Zn in 9GMX
Zn in 9GMW
Zn in 9JEJ
Zn in 9ERF
Zn in 9ERE
Zn in 9EGV
Zn in 9EGW
© Copyright 2008-2020 by atomistry.com
Home   |    Site Map   |    Copyright   |    Contact us   |    Privacy