Atomistry » Magnesium » PDB 2bt6-2c3y » 2by2
Atomistry »
  Magnesium »
    PDB 2bt6-2c3y »
      2by2 »

Magnesium in PDB 2by2: Is Radiation Damage Dependent on the Dose-Rate Used During Macromolecular Crystallography Data Collection

Enzymatic activity of Is Radiation Damage Dependent on the Dose-Rate Used During Macromolecular Crystallography Data Collection

All present enzymatic activity of Is Radiation Damage Dependent on the Dose-Rate Used During Macromolecular Crystallography Data Collection:
3.2.1.1;

Protein crystallography data

The structure of Is Radiation Damage Dependent on the Dose-Rate Used During Macromolecular Crystallography Data Collection, PDB code: 2by2 was solved by H.-K.S.Leiros, J.Timmins, R.B.G.Ravelli, S.M.Mcsweeney, with X-Ray Crystallography technique. A brief refinement statistics is given in the table below:

Resolution Low / High (Å) 20.00 / 1.5
Space group P 21 21 21
Cell size a, b, c (Å), α, β, γ (°) 59.418, 66.529, 152.522, 90.00, 90.00, 90.00
R / Rfree (%) 14.8 / 17.7

Magnesium Binding Sites:

The binding sites of Magnesium atom in the Is Radiation Damage Dependent on the Dose-Rate Used During Macromolecular Crystallography Data Collection (pdb code 2by2). This binding sites where shown within 5.0 Angstroms radius around Magnesium atom.
In total only one binding site of Magnesium was determined in the Is Radiation Damage Dependent on the Dose-Rate Used During Macromolecular Crystallography Data Collection, PDB code: 2by2:

Magnesium binding site 1 out of 1 in 2by2

Go back to Magnesium Binding Sites List in 2by2
Magnesium binding site 1 out of 1 in the Is Radiation Damage Dependent on the Dose-Rate Used During Macromolecular Crystallography Data Collection


Mono view


Stereo pair view

A full contact list of Magnesium with other atoms in the Mg binding site number 1 of Is Radiation Damage Dependent on the Dose-Rate Used During Macromolecular Crystallography Data Collection within 5.0Å range:
probe atom residue distance (Å) B Occ
A:Mg1608

b:13.7
occ:0.85
O A:HOH2844 2.1 22.3 1.0
O A:HOH2889 2.1 21.9 1.0
OD1 A:ASP540 2.2 14.0 1.0
CG A:ASP540 3.3 12.6 1.0
OD2 A:ASP540 3.6 13.3 1.0
NZ A:LYS572 4.1 20.4 0.5
O A:HOH2847 4.2 35.8 1.0
N A:GLY541 4.2 9.2 1.0
O A:HOH2849 4.2 14.5 1.0
CE A:LYS572 4.2 20.4 0.5
O A:HOH2845 4.4 17.5 1.0
C A:ASP540 4.4 8.7 1.0
CB A:ASP540 4.6 8.7 1.0
CA A:GLY541 4.6 9.2 1.0
CD A:LYS572 4.7 17.6 0.5
CA A:ASP540 4.7 9.3 1.0
O A:ASP540 4.9 7.6 1.0
O A:HOH2846 5.0 34.1 1.0

Reference:

H.-K.S.Leiros, J.Timmins, R.B.G.Ravelli, S.M.Mcsweeney. Is Radiation Damage Dependent on the Dose-Rate Used During Macromolecular Crystallography Data Collection? Acta Crystallogr.,Sect.D V. 62 125 2006.
ISSN: ISSN 0907-4449
PubMed: 16421442
DOI: 10.1107/S0907444905033627
Page generated: Tue Aug 13 22:06:47 2024

Last articles

Zn in 9JPJ
Zn in 9JP7
Zn in 9JPK
Zn in 9JPL
Zn in 9GN6
Zn in 9GN7
Zn in 9GKU
Zn in 9GKW
Zn in 9GKX
Zn in 9GL0
© Copyright 2008-2020 by atomistry.com
Home   |    Site Map   |    Copyright   |    Contact us   |    Privacy